Energy range of the measures of photon radiation
|
60 keV - 3 MeV |
|
Ambient dose equivalent rate (ADER) of photon radiation measurement range
|
0.1 - 30 μSv/h (for energy 662 keV) |
|
Accuracy of photon radiation ADER measurement
|
±30 % |
|
False alarm rate
|
1/1000 |
|
Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability
at gamma radiation background 0,1 μSv/h
at source speed 5 km/h
133Ba - 40 kBq
137Cs - 50 kBq
60Co - 24 kBq |
|
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability
at gamma radiation background 0,1 μSv/h
at source speed 15 km/h
133Ba - 165 kBq
137Cs - 200 kBq
60Co - 95 kBq |
|
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3.5 m
|
with 0.5 probability and at least 0.95 confidence probability
at gamma radiation background 0,25 μSv/h
when source is shielded with 1 mm of steel
at source speed 10 km/h
133Ba - 340 kBq
137Cs - 410 kBq
60Co - 210 kBq
in long-dwell scan mode
133Ba - 60 kBq
137Cs - 70 kBq
60Co - 35 kBq |
|
Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability
at gamma radiation background 0,1 μSv/h
at source speed 15 km/h
133Ba - 315 kBq
137Cs - 390 kBq
60Co - 190 kBq
in long-dwell scan mode
133Ba - 53 kBq
137Cs - 67 kBq
60Co - 32 kBq |
|
Number of detection units
|
2 |
|
PC communication
|
Ethernet, WiFi |
|
Ingress protection
|
IP65 |
|
Mean recovery time
|
no more then 60 min |
|
Mean service lifetime
|
15 years |
|
Mean time between failyres, no less than
|
20 000 h |
|
Atmospheric pressure
|
from 84 to 106.7 kPa |
|
Operating temperature
|
-30 up to +50 °C
-50 up to +50 °C with heating module |
|
Humidity
|
98 % at +40 °С and lower temperature |
|
Power source
|
AC mains, built-in accumulator |
|
Supply voltage
|
90 - 132 V or 180 - 264 V, 47 - 63 Hz |
|
Power consumption
|
no more then 80 V⋅A (without video surveillance and heating)
no more then 940 V⋅A (with video surveillance and heating) |
|
Battery Lifetime
|
3 h |