Thiết bị đo nhiệt độ và áp suất chân không DPM4

Trọng lượng nhẹ, kích thước nhỏ gọn và hoạt động bằng pin

Cick vào đây để tải Catalog sản phẩm

tabs

Tổng quan
  • Palm Size
  • High accuracy
  • Differential pressure, vacuum, and temperature measurements
  • Multiple user-selectable units of measurements
  • Simultaneous display of multiple parameter measurements
  • Leak detection/leak-rate calculation
  • RS232 for computer control
  • Pressure measurements from -700 mmHg to +5000 mmHg range (applies to the 1G and 2G models only)
  • Barometric-pressure, flow, and humidity measurements (applies to the 2G and 2H models only)

 

Thông số kỹ thuật

General Specifications
DPM4 Pressure Vacuum Temperature Tester
General Information
Temperature Requirements:
15° C to 35° C when operating 0° C to 50° C in storage
Display/Control:
LCD graphic display, 128 x 32 pixel
Data Input/Outputs (1):
Bi-directional RS-232C for Computer control
Power:
9 Volt Alkaline Battery RG9 or Battery eliminator
Case:
ABS plastic case
Weight:
0.4 kg / 0.9 lbs. with battery
Dimensions (D x W x H):
34 mm x 94 mm x 156 mm (1.3 in x 3.7 in x 6.1 in)
Specifications
DPM4 Model 1H or 2H
Operating Range
-350 mmHg to 350 mmHg
Accuracy
0.3 % of range
Resolution
0.1 mmHg
Units of measure
mmHg, mBar, cmH 2 O, PSI, InHg, InH 2 O, kgcm 2 and kPa
DPM4 Model 1G or 2G
Operating range:
-700 mmHg to 5000 mmHg
Accuracy
  • 0.3 % of range for temperatures from 21 º C to 25 ° C and relative humidity from 30 % to 70 %;
  • 0.3 % of range plus 0.02 % of range per degree C for temperature < 21 ° C or > 25 ° C with relative humidity from 30 % to 70 %
Resolution:
0.5 mmHg
Units of measure:
mmHg, mBar, cmH 2 O, PSI, InHg, InH 2 O, kgcm 2 and kPa
Temperature Measurement
All Models (DPM4-1H, 1G, 2H, 2G)
Operating range
-40 º C to 200 º C
Accuracy
(2 % of reading, 0.5 º C)
Resolution
0.1 ° C and ° F
Units of measure
° C and ° F

Use standard external temperature probe type PT-100 or PT-1000 (DIN/IEC 751 Class A) for temperature measurements in ° C or ° F

PT-100
-50 º C to +200 º C
Accuracy
  • 0.23 º F @ 212 º F (0.13 º C @ 100 º C)
  • 0.18 º F @ 32 º F (0.1 º C @ 0 º C)
  • 0.36 º F @ 212 º F (0.2 º C @ 100 º C)
PT-1000
-50 º C to +200 º C
0.3 º C (0.5 º F)
DPM4 Model 2G or 2H

It is possible to compensate for the sea level and calibrate for offsets.

Operating Range
380 mmHg to 825 mmHg
Accuracy
2 % of reading 1LSD
Resolution
0.1 mmHg
Units of Measure
mmHg, mBar, inHg and hPa
Gas Flow

Measures with an embedded sensor with 11 calibration points to compensate nonlinearity. Calibration constants stored in firmware.

Operating range
-750 to 750 ml/min
Accuracy
1% of range or 5% of reading, whichever is greatest
Compatibility
0.1 ml/min
Resolution
Gas: Air, N 2 , O 2 , CO, NO, CO 2 , N 2 O, and NO 2
Units of measure
ml/min (or SCCM - Standard Cubic Centimeters per Minute)
Relative Humidity

An integrated sensor in the instrument determines relative humidity measurements.

Operating range
12 % to 95 % RH
Accuracy
3.5 % of reading 2 % RH
@ 25 º C for RH between 12 % and 95 % RH
Resolution
0.1% RH
Gas compatibility
Air
Units of measure
% RH
Ordering Information
Standard Accessories 

 

PT-100 Temperature Probe

PT-1000 Temperature Probe

Tubing Kit with Inflation Bulb

14622 Tubing Kit with Inflation Bulb (part# 2461946)for testing NIBP. Kit includes:4095363 Bulb & Valve Assembly (Briggs Sphygmomanometers)3539038 2461932 Luer Lock (male 0.106 ID)3539045 2461933 Luer Lock (barbed female 0.107 ID2215997 Quick-disconnect fitting (1/8")2216266 49303 T-fitting (1/8" X3 PP)889050 PVC Sleeving (.125 clear)3569098 MSJ-4406 Dual Lock 400 (Lockfast #SJ-3541)1259450 Factory base warranty (1 year)