Features |
Battery life hours |
8 hrs |
Charge time in hours |
5 hrs, typical |
Memory |
internal memory |
Connection type |
USB, Micro-B device port |
Weight |
3.6 lb (1.6 kg) |
Display |
17.8 cm (7 in) |
Single full-Range channel |
√ |
Flow |
Full Range flow channel (includes both low and high flow, flow specifications are with laminar flow input) |
Range |
0 to ±200 slpm |
Accuracy |
±2.0% of rdg or 0.04 slpm |
Range |
200 to 300 slpm, -200 to -300 slpm,
-22 to - 14 slpm, +7.5 to +9.5 slpm |
Accuracy |
2.5% of rdg |
Volume |
Range |
±100 l |
Accuracy |
±2.0 % or 0.02 l |
Pressure |
High pressure |
Range |
-0.8 to 10 bar |
Accuracy |
±1 % or ±0.007 bar |
Differential low pressure |
Range |
±160 mbar |
Accuracy |
±0.5 % or ±0.1 mbar |
Airway pressure |
Range |
±160 mbar |
Accuracy |
±0.5 % or ±0.1 mbar |
Barometric pressure |
Range |
550 to 1240 mbar |
Accuracy |
±1 % or ±5 mbar |
Other |
Temperature |
Range |
0 to 50 °C |
Accuracy |
±0.5 °C |
Resolution |
0.1 °C |
Humidity |
Range |
0 to 100 % RH |
Accuracy |
±3 % RH (20 to 80 % RH)
±5 % RH (20< or >80 % RH) |
Oxygen |
Range |
0 to 100 % |
Accuracy |
±1 % |
Breath parameters |
Inspiratory tidal volume Range |
0 to 60 l |
Inspiratory tidal volume Accuracy |
±2.0 % or 5 ml |
Expiratory tidal volume Range |
0 to 60 l |
Expiratory tidal volume Accuracy |
±2.0 % or 5 ml |
Minute volume Range |
0 to 100 l |
Minute volume Accuracy |
±2.0 % or 5 ml |
Breath rate Range |
1 to 1500 bpm |
Breath rate Accuracy |
±1 % |
Inspiratory to expiratory time ratio (I:E) Range |
1:300 to 300:1 |
Inspiratory to expiratory time ratio (I:E) Accuracy |
±2 % or 0.1 |
Peak inspiratory pressure (PIP) Range |
±160 mbar |
Peak inspiratory pressure (PIP) Accuracy |
±0.75 % or 0.1 mbar |
Inspiratory pause pressure Range |
±160 mbar |
Inspiratory pause pressure |
±0.75 % or 0.1 mbar |
Mean airway pressure Range |
±160 mbar |
Mean airway pressure Accuracy |
±0.75 % or 0.1 mbar |
Positive end expiratory pressure (PEEP) Range |
±160 mbar |
Positive end expiratory pressure (PEEP) Accuracy |
±0.75 % or 0.1 mbar |
Lung compliance Range |
0 to 1000 ml/mbar |
Lung compliance Accuracy |
±3 % or 0.1 ml/mbar |
Inspiratory time Range |
0 to 60 s |
Inspiratory time Accuracy |
0.02 s |
Inspiratory hold time Range |
0 to 60 s |
Inspiratory hold time Accuracy |
1 % or 0.1 s |
Expiratory time Range |
0 to 90 s |
Expiratory time Accuracy |
0.5 % or 0.01 s |
Expiratory hold time Range |
0 to 90 s |
Expiratory hold time Accuracy |
0.02 s |
Peak expiratory flow Range |
±300 lpm |
Peak expiratory flow Accuracy |
±2.0 % or 0.04 lpm |
Peak inspiratory flow Range |
±300 lpm |
Peak inspiratory flow Accuracy |
±2.0 % or 0.04 lpm |
Environmental |
Operating temp |
10 °C to 40 °C |
Storage temp |
-20 °C to 60 °C |
Operating humidity |
10 to 90 % non-condensing |
Storage humidity |
5 to 95 % non-condensing |
Gas corrections |
Gas types |
ATP (ambient temp/pressure, actual humidity) |
Air |
ATPD (ambient temp/pressure, dry) Nitrogen (N2) |
ATPS (ambient temp/pressure, saturated) |
Nitrous Oxide (N2O) |
STP20 (20 °C temp/pressure 760 mmHg, actual humidity) |
Carbon Dioxide (CO2) |
STP21 (21 °C temp/pressure 760 mmHg, actual humidity) |
Oxygen (O2) |
STPD0 (0 °C temp/pressure 760 mmHg, dry) |
Argon |
STPD20 (20 °C temp/pressure 760 mmHg, dry) |
Heliox (21 % O2, 79% He) |
STP or STPD21 (21 °C temp/pressure 760 mmHg, dry) |
Oxygen/Nitrogen |
BTPS (body temp 37 °C/ambient pressure 760 mmHg, saturated) |
Oxygen/Nitrous Oxide |
BTPD (body temp 37 °C/ambient pressure 760 mmHg, dry) |
Oxygen/Helium |